Home

Sobre Nós

Produtos

Serviços

Suporte

Contato
 
Entrega Imediata
 

 

Quadro Comparativo entre os Hypot série 3800

 

Modelo

 

3805

3865

3870

 

3880

 

 

Hypot 3805

Hypot 3805

Hypot 3805

Hypot 3880

Test Capabilities

AC Hipot
Ground Continuity

AC Hipot
DC Hipot
Ground Continuity

AC Hipot
DC Hipot
Ground Continuity
Insulation Resistance

AC Hipot 500 VA
Ground Continuity

Test Specifications

AC Hipot
Voltage Output = 0-5000VAC
Leakage Current Limits = 0.00-20.0mA
Output Frequency = 50/60Hz

Ground Continuity
Current = DC 0.1A ± 0.01A, fixed
Resistance Limits = 0.0Ω – 1.50Ω

AC Hipot
Voltage Output = 0-5000VAC
Leakage Current Limits = 0.00-20.0mA
Output Frequency = 50/60Hz

DC Hipot
Voltage Output = 0-6000VDC
Leakage Current Limits = 1µA – 7.500mA
DC Ripple ≤ 5% Ripple RMS at 6KVDC @ 7.5mA, Resistive Load

Ground Continuity
Current = DC 0.1A ± 0.01A, fixed
Resistance Limits = 0.0Ω – 1.50Ω

AC Hipot
Voltage Output = 0-5000VAC
Leakage Current Limits = 0.00-20.0mA
Output Frequency = 50/60Hz

DC Hipot
Voltage Output = 0-6000VDC
Leakage Current Limits = 1µA – 7.500mA
DC Ripple ≤ 5% Ripple RMS at 6KVDC @ 7.5mA, Resistive Load

Ground Continuity
Current = DC 0.1A ± 0.01A, fixed
Resistance Limits = 0.0Ω – 1.50Ω

Insulation Resistance
Voltage Output = 30 – 1000VDC
Resistance Range = 1MΩ - 5GΩ

AC Hipot
Voltage Output = 0-5000VAC
Leakage Current Limits = 0.00-99.99mA
Output Frequency = 50/60Hz

Ground Continuity
Current = DC 0.1A ± 0.01A, fixed
Resistance Limits = 0.0Ω – 1.50Ω

Safety

Safety Interlock
SmartGFI®
Security Access

Safety Interlock
SmartGFI®
Security Access

Safety Interlock
SmartGFI®
Security Access

Safety Interlock
SmartGFI®
Security Access

Productivity

Programmable Memory
Arc Detection
Single Step
FailCHEK®
Cal Alert®

Programmable Memory
Arc Detection
Single Step
FailCHEK®
Cal Alert®

Programmable Memory
Arc Detection
Single Step
FailCHEK®
Cal Alert®

Programmable Memory
Arc Detection
Single Step
FailCHEK®
Cal Alert®

Automation

USB

USB

USB

USB

Warranty

Standard 3 Year Warranty

Standard 3 Year Warranty

Standard 3 Year Warranty

Standard 3 Year Warranty

Production Test Compliance

IEC/UL 60335-1
IEC 60598-1
IEC/UL 60601-1
IEC/UL 60950-1
IEC/UL 61010-1
IEC 61851-1
UL 45A
UL 2202
UL 1598/CSA C22.2 No. 250.0-08

IEC/UL 60335-1
IEC 60598-1
IEC/UL 60601-1
IEC/UL 60950-1
IEC/UL 61010-1
IEC 61851-1
UL 45A
UL 2202
UL 1598/CSA C22.2 No. 250.0-08

IEC/UL 60335-1
IEC 60598-1
IEC/UL 60601-1
IEC/UL 60950-1
IEC/UL 61010-1
IEC 61851-1
UL 45A
UL 2202
UL 1598/CSA C22.2 No. 250.0-08

IEC/UL 60335-1
IEC 60598-1
IEC/UL 60601-1
IEC/UL 60950-1
IEC/UL 61010-1
IEC 61851-1
UL 45A
UL 2202
UL 1598/CSA C22.2 No. 250.0-08

Type Test Compliance

BS EN 60204-1
IEC/UL 60601-1
IEC 61730-1
UL 1703
UL 2202
UL 1598/CSA C22.2 No. 250.0-08

IEC/UL 60601-1
IEC/UL 60950-1
IEC 61851-1
UL 45A
UL 2202
UL 1598/CSA C22.2 No. 250.0-08

BS EN 60204-1
IEC/UL 60601-1
IEC 61730-1
UL 1703
UL 2202
UL 1598/CSA C22.2 No. 250.0-08

IEC/UL 60335-1
IEC 60598-1
IEC/UL 60601-1
IEC/UL 60950-1
IEC/UL 61010-1
IEC 61851-1
UL 45A
UL 2202
UL 1598/CSA C22.2 No. 250.0-08

In the Box

Hypot Instrument
High Voltage Cable
Return Cable
Fuse
USB Cable
Line Cord
Adapter Box
Interlock Disable Key

Hypot Instrument
High Voltage Cable
Return Cable
Fuse
USB Cable
Line Cord
Adapter Box
Interlock Disable Key

Hypot Instrument
High Voltage Cable
Return Cable
Fuse
USB Cable
Line Cord
Adapter Box
Interlock Disable Key

Hypot Instrument
High Voltage Cable
Return Cable
Fuse
USB Cable
Line Cord
Adapter Box
Interlock Disable Key

Instrument Dimensions

8.5 x 3.5 x 11.9 in
(215 x 88.1 x 300 mm)

8.5 x 3.5 x 11.9 in
(215 x 88.1 x 300 mm)

8.5 x 3.5 x 11.9 in
(215 x 88.1 x 300 mm)

16.93 x 5.20 x 11.84 in
(430 x 132 x 300 mm)

Weight

12 lbs (5.46 kg)

12 lbs (5.46 kg)

12 lbs (5.46 kg)

50 lbs (23 kg)

Shipping Dimensions & Weight (out-the-door)

Dimension: 19 x 15 x 10 in
Weight: 14 lbs (7 kg)

Dimension: 19 x 15 x 10 in
Weight: 14 lbs (7 kg)

Dimension: 19 x 15 x 10 in
Weight: 14 lbs (7 kg)

Dimension: 23 x 18 x 11 in
Weight: 49 lbs (22 kg)

Options

OPT 04 - 3mA AC/DC Output
OPT 05 - 5mA AC/DC Output
OPT 06 - 5Ω Continuity
OPT 14 - Mimic H3 Command Set
OPT 15 - PLC Ready Output
OPT 16 - 7 Memory Remote Select

OPT 04 - 3mA AC/DC Output
OPT 05 - 5mA AC/DC Output
OPT 06 - 5Ω Continuity
OPT 14 - Mimic H3 Command Set
OPT 15 - PLC Ready Output
OPT 16 - 7 Memory Remote Select

OPT 04 - 3mA AC/DC Output
OPT 05 - 5mA AC/DC Output
OPT 06 - 5Ω Continuity
OPT 14 - Mimic H3 Command Set
OPT 15 - PLC Ready Output
OPT 16 - 7 Memory Remote Select

OPT 04 - 3mA AC/DC Output
OPT 05 - 5mA AC/DC Output
OPT 06 - 5Ω Continuity
OPT 14 - Mimic H3 Command Set
OPT 15 - PLC Ready Output
OPT 16 - 7 Memory Remote Select